3 Ton, 15 to 16 SEER, Two-Stage Condenser, Comfort Bridge Technology System Compatible, R-410A Refrigerant, Northern Sales Only
3 Ton, 15 to 16 SEER, Two-Stage Condenser, Comfort Bridge Technology System Compatible, R-410A Refrigerant, Northern Sales Only
Model: Direct Comfort DC-GSXC160361
Model: Direct Comfort DC-GSXC160361
Delivers reliable cooling to every corner of your home
Sturdy design for long term durability
Built for simple installation and easy maintenance
Peace of mind with 10 year warranty (with registration)
Was: $2,340.00
Savings: $70.00
Only 4 left in stock
- Pro Installation (Learn More)
The Direct Comfort by Goodman® brand DC-GSXC16 16 SEER Central Air Conditioner uses the environmentally friendly refrigerant R-410A and features energy efficiencies and operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. The DC-DSXC16 features the two-stage, high-efficiency scroll compressor, which provides improved temperature and humidity control. This unit is designed for the consumer who desires superior comfort, quiet operation, and environmentally friendly air conditioning performance.
This central air conditioning condenser requires an indoor air handler or evaporator coil as part of a complete system. What tonnage coil or air handler should you use? It depends on two factors about the outside portion of the central air conditioning system: 1) the tonnage, and 2) the efficiency rating (listed as "SEER"). Usually, high efficiency central air conditioning condensers are required to use a larger tonnage evaporator coil than the tonnage of the outside central air condenser. (For example, a 2 ton central air conditioning condenser might be paired with a 3 ton or 3.5 ton evaporator coil.) To find the specific coils or air handlers that are recommended by Direct Comfort by Goodman for this central air conditioning condenser, please click on the Accessories tab above.
In order to achieve the 16 SEER efficiency this central air conditioner must be installed with the manufacturer recommended evaporator coil, a Direct Comfort by Goodman variable speed furnace, variable speed air handler, or variable speed modular blower and thermostatic expansion valve (TXV). (See the Accessories tab above for most compatible products, or Direct Comfort by Goodman's spec sheet found under the Documents tab above to verify central air conditioning efficiency with particular equipment combinations.) A 16 SEER system will reduce your electric bill approximately 7% - 8% more than a 15 SEER system.
This is a communicating piece of equipment and to achieve full efficiency and functionality it must be paired with a Direct Comfort by Goodman communicating furnace, air handler, or modular blower with evaporator coil. If pairing this with an alternate indoor unit you must verify that the indoor unit is compatible with a 2 stage cooling system and you will need part 0130M00485 for the installation.
Need help putting a complete central air conditioning system together? Use our easy System Selector and we’ll do it for you!
Please note that this air conditioning equipment comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. Yes you can purchase this equipment without being EPA certified. If you are mechanically inclined you may perform about 90% of the equipment installation yourself. However we strongly recommend that a professional heating / cooling contractor do the final part of the installation, including the managing of refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this central air conditioner validates your warranty with Alpine.
Standard Features of this Central Air Conditioner
- Two-Stage high efficiency scroll compressor
- Two-Speed condenser fan motor
- Integrated communicating ComfortBridge™ Technology
- Commissioning and diagnostics via indoor board Bluetooth with the CoolCloud™ phone and tablet application
- Factory-installed filter dryer
- Factory-installed transformer
- Factory-installed high and low-pressure switches
- High-density foam compressor sound blanket
- Fully charged for 15’ of tubing length
- Factory-installed sensors monitoring coil and ambient temperature
- Contactor with lug connection
- In communicating mode, only two low voltage wires to the outdoor unit are required
- AHRI Certified - ETL Listed
- Ground lug connection
- Copper tube & enhanced aluminum fin coil
- Customized control algorithms
Cabinet Features
- Heavy-gauge galvanized steel cabinet and louvered coil guards
- Service valves with sweat connections and easy-access gauge ports
- Engineered sound control top design
- Wire fan discharge grille
- Baked-on powder-paint finish with 500-hour salt-spray approval
- Single-panel access to controls with space for field-installed accessories
- Service port and controls are accessible while unit is operating
- Compact footprint
- Rust-resistant screws
- When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane-type winds
Enjoy free shipping on any accessories purchased with the Direct Comfort DC-GSXC160361.
Required Components for Installation
- GSXC16 Installation Instructions(PDF, 720 KB)
- GSXC16 Spec Sheet(PDF, 3.30 MB)
- GSXC GSZC GVXC GVZC Warranty 4/22(PDF, 632 KB)
- 2023 Efficiency Requirements Important Please Read(PDF, 176 KB)
- Goodman GSXC16 Brochure 08-2022(PDF, 1.03 MB)
- Wire Gauge Sizes(PDF, 40.9 KB)