2 Ton Heat Pump, 70,000 BTU 96% AFUE Gas Furnace, 17 SEER / 15.6 SEER2 Upflow Dual Fuel Split System Kit
2 Ton Heat Pump, 70,000 BTU 96% AFUE Gas Furnace, 17 SEER / 15.6 SEER2 Upflow Dual Fuel Split System Kit
Model: Blueridge BHP17L24P-BG961UH070BE12-BC4X30B (Kit No. D1703)
Model: Blueridge BHP17L24P-BG961UH070BE12-BC4X30B (Kit No. D1703)
Was: $4,090.00
Savings: $110.00
- Pro Installation (Learn More)
To use LP fuel, this unit requires an LP Conversion Kit. See Accessories
When you consider a Blueridge system, quality and value are a given. You’re getting peace of mind with great features and a smart design—and best of all, you get it right now. When you think about everything Blueridge delivers, your decision is easy. With Blueridge, all your heating and cooling questions are answered. The performance and reliability you want are right here, and ready to go to work.
Blueridge heat pumps are built in North America for an unbeatable combination of quality and price. They provide highly efficient, powerful cooling during hot weather, and when the weather turns cold, onboard technology reverses the refrigerant cycle to provide heat, and at a fraction of the cost of many alternative heat sources (particularily alternate forms of electric heat, propane, and fuel oil). Blueridge furnaces are built in North America and are designed for efficient and quiet operation along with ease of installation and maintenance.
This system is designed for an upflow application with the furnace standing up straight and blowing air into ducts above it, It consists of a heat pump, a gas furnace and an evaporator coil.
This is a certified, high efficency, 15.6 SEER2 matching dual fuel system. A dual fuel system provides the best of both worlds. It will use energy efficient heat pump generated heat when the weather is cold outside and a dual fuel compatible thermostat (accessorized below) will switch off the heat pump and turn on the gas furnace on the coldest days. This combination provides optimal heating for your home regardless of the outdoor conditions and can save you anywhere from 10-30% on your heating bills.
The furnace is designed to use natural gas but it can be converted to use propane. The propane (lp) conversion kit and other install components are in Accessories section below.
We design our system bundles to provide homeowners and contractors with a new HVAC system in one simple purchase. If you'd like help picking out the best option for your needs, give us a call at 1 800 865 5931. Our system design consultants have decades of combined experience helping homeowners select the right equipment. If you have any questions, concerns or just need some guidance, please get in touch with us. We're here to help.
Heat Pump Standard Features:
-
High-efficiency scroll compressor
-
R410A refrigerant
-
Grommet mounted compressor for quiet operation
-
Internally protected against high temperature motor overload conditions
-
Full metal louvered panel with 2 screws to remove for ease of coil cleaning and service
-
Corner-mounted controls for easy service
-
Baked polyester paint finished over galvanized steel for maximum durability
-
External gauge ports for easy service
-
Removable service panel for internal access
-
Omniguard™ total corrosion protection technology designed coil
-
Enhanced tube-and-fin coil design featuring MHT™ Technology
-
Lanced fins for maximum heat transfer
-
Factory tested for leakproof construction
-
Raised coil prevents debris from impeding airflow
-
Factory installed high and low pressure switches
-
Thread-on pressure switches with Schrader core for simple, quick replacement
-
Factory installed filter drier
-
Fan orifice for smoother airflow and sound level reduction
-
Charged for 15 feet of line set
-
Discharge muffler for quiet operation
-
Quiet Shift™ capable to reduce noise during defrost
Furnace Features:
-
Efficient constant torque ECM blower motor
-
Easily removable slide-out blower design
-
Dynamically balanced blower wheel with resilient motor mounts for smooth and quiet operation
-
Aluminized steel primary heat exchanger with crimped non welded construction
-
Integrated ignition and fan control
-
Self diagnostics saving last 10 fault codes regardless of power interruption
-
Hot surface ignition system uses silicon nitride ignitor
-
Control features 120 volt electronic air cleaner and humidifier terminals
-
Control circuit is fuse protected
-
Color coded control wiring
Coil Features:
-
Dedicated upflow
-
Factory installed TXV for quick installation in high efficiency applications
-
Tightly sealed, painted steel cabinet with wall to wall insulation to ensure <2% air leakage
-
Single protruding right side dual drain port for easy installation and service access
-
Omniguard™ Total Corrosion Protection* our advanced evaporator coil helps protect against leaks and corrosion for long term performance
-
Microban® antimicrobial additive in the drain pan to resist mold and mildew growth
-
Aluminum tubing, hairpins, distributors and header tubes. Copper refrigerant connections for easy brazing to both liquid and suction lines
-
Preformed flanges in outlet for quick and easy plenum connections
-
One of the lowest water retention drain pans in the industry to minimize mold and mildew growth
-
Interlocking door assemblies and snug line seal grommets to minimize air leakage
-
Foil-face insulation for easy cleaning
-
Tubing located at door split for easy coil service or cleaning
-
All drain pans are compatible with UV lights
-
All piston coils are compatible with R22 or R410a
-
10-year limited parts warranty available when applied with a system. See limited warranty document for details.
These components were selected by HVAC specialists to maximize their performance and efficiency. This system is certified under AHRI # 210441245 to give you 15.6 SEER2
Please note that this heat pump comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. You can purchase this equipment without being EPA certified, and if you are mechanically inclined you may perform about 90% of the equipment installation yourself. However we strongly recommend to have a professional heating/cooling contractor do the final part of the installation including managing the refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this heat pump validates your warranty with Alpine.
Click the links below to check each components' specifications and documentation.
This system includes:
|
BC4X30B |
|
|
BG961UH070BE12 |
|
|
BHP17L24P |
|
WARRANTY
10 year limited warranty with online registration
5 year limited warranty without online registration
Enjoy free shipping on any accessories purchased with the Blueridge BHP17L24P-BG961UH070BE12-BC4X30B (Kit No. D1703).
Required Components for Installation
- Blueridge Gas Furnace Owner Information(PDF, 286 KB)
- Blueridge Long Lineset Instructions(PDF, 667 KB)
- Blueridge BG961 Specifications Sheet(PDF, 796 KB)
- Blueridge AHRI Certificate 210441245(PDF, 143 KB)
- Blueridge BG961UH Installation Instructions 11/2023(PDF, 3.15 MB)
- Blueridge High Efficiency Gas Furnace Brochure 2024(PDF, 721 KB)
- Wire Gauge Sizes(PDF, 40.9 KB)
- Blueridge Unitary Equipment Warranty (Ver. 2.2)(PDF, 551 KB)
- Blueridge BHP17L Spec Sheet(PDF, 1.54 MB)
- Blueridge BHP17L Installation Manual(PDF, 1.30 MB)
- Blueridge Evaporator Coil Spec Sheet(PDF, 601 KB)
- Blueridge Upflow Coil Installation Manual(PDF, 938 KB)