Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliances.
Features
- Control ignition sequence and gas control operation.
- Generate high voltage potential for main burner ignition.
- Lockout after one trial for ignition if main burner fails to ignite.
- Reset from thermostat after lockout.
- Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less.
Specs
System Information
Lockout Timing
21 seconds
Flame Sense
Single Rod
Fuel Type
Liquid Propane / Natural Gas
Ignition Type
Direct Spark
Performance
Maximum Ambient Temperature
175 °F
Minimum Ambient Temperature
-40 °F
Electrical Information
Frequency
60 Hz
Voltage
24 Volts
Product Dimensions
Width
4 1/16 Inches
Depth
1 15/16 Inches
Height
5 1/4 Inches
Product Weight
.75 lbs