12,000 BTU Cooling (1 Ton), 10,200 BTU Heating (0.9 Ton), 10.7 EER PTAC, 3.4kW Heat Strip, R-410A Refrigerant
12,000 BTU Cooling (1 Ton), 10,200 BTU Heating (0.9 Ton), 10.7 EER PTAC, 3.4kW Heat Strip, R-410A Refrigerant
Model: Friedrich PDE12K3SF
Engineered for quieter performance, the Friedrich PTAC features a tangential blower wheel, universal heater options, and modular component design for easier service. Hotels focused on maximizing room revenues and minimizing guest complaints buy Friedrich PTAC:
- 2-year parts and labor warranty
- Sound reduction technology for quiet operation
- Separate thermostat limits for cooling and heating modes
- Dehumidification mode removes up to 3.2 pts per hour
- Diamonblue™Advanced Corrosion Protection on coils
- Cooling (7700-15000 Btu) and Heating (6300-13300 Btu)
- All models fit standard 42-inch sleeves (no baffle kit)
The PTAC units slide into a standard, pre-existing 16” x 42” wall sleeve and include intuitively configured controls. New installations require a wall sleeve and grille which can be purchased as <<Accessories>>.
Friedrich PTACs are known for being feature-rich and backed by an AC-focused manufacturer. Our new models build on these strengths, with advanced engineering that delivers impressively quiet performance with expanded comfort settings.
Here are just some of the enhanced features:
- Reduced sound levels: The two-motor design – one motor inside, one outside – allows the indoor motor to run at slower speeds, which sharply reduces indoor sound levels. Plus, the motors are permanently lubricated for quieter operation and increased durability.
- More comfort choices, quieter operation: Our 3-speed fan (cooling and heating modes) has nearly five times the surface area of a typical PTAC fan, allowing for more uniform airflow over a wider path. The result is faster, more even air distribution and quieter airflow. Guests/residents will appreciate having more comfort options. Plus, the soft start/stop fan delay reduces transitional noise usually associated with compressor start-up.
- Increased energy savings: Models have EERs up to 12.0 and COPs up to 3.4. Separate thermostat limits for cooling and heating provide greater control over temperature ranges. Of course, centralized desk control and compatibility with energy management systems can boost efficiency and lower operational costs.
- A universal heater/power cord simplifies installation, ordering: Installers can change the heat output simply by changing the standard power cord to the desired size. The optional cords connect as easily as a phone jack. Distributors can stock fewer PTAC models and optional power cords instead of numerous PTAC models. (Note: All wiring and building connections must be properly sized to accommodate the power cord. See model specifications for details.
Plus, all capacities can fit standard 42-inch sleeves without the added expense of a baffle kit*.
-
Comfort & Dehumidification
- Quieter operation
- Intuitive controls
- Even heat monitoring checks room temperature and automatically adds a heat boost if necessary
- Separate thermostat settings (limiting) for cooling and heating nodes
- Samples the room temperature every 9 minutes to monitor and maintain desired temperature
- “Instant Heat” in heat pump mode quickly heats a room to the desired temperature
- Dehumidification mode removes up to 3.2 pts per hour
- Optional constant fan mode for additional comfort options
- Reversible indoor air louvers for an additional airflow direction option
-
Sound Reduction Technology
- New 2-motor design allows the indoor motor to run at slower speeds, which reduces indoor sound levels
- The quiet, efficient compressor is mounted on vibration isolators, which absorb vibration-causing noise
- Permanently lubricated dual motors reduce noise
- New elongated fan moves air over a wider area so it's quieter
- Fan turns on before the compressor starts to muffle the sound
- High-density insulation helps keep outdoor noise outside
-
Durability
- Diamonblue Technology advanced anti-corrosion protection protects the outdoor coil against deterioration and extends unit life, especially in harsh coastal environments
- Faultless surehold Front cover system attaches securely
- Room Freeze Protection initiates heat if room temperature falls to 40 °F in an unoccupied room
- Random compressor resistant protects
electrical systems - Stainless Steel endplates on both indoor and outdoor coil
- Indoor coil frost sensor protects the compressor
- Durable front panel with break-proof control door and design
- Permanently lubricated fan motors
- Tamper-resistant grille
- Durable, powder coat paint finish
-
Health and IAQ
- Fresh-air vent
- Two washable, antimicrobial filters
-
Energy Usage: Management
- Increase or decrease electric heat output by changing the power cord
- Set separate heat and cool range limits
- Desk control ready
- Energy Management System Compatible
- Electronic defrost control
-
Maintenance and Installation Features
- Service error code storage
- May be installed flush with floor
- Reversible indoor air louvers
- Improved weather barrier
- Nationwide Service Network
- Modular design and pop out wiring modules
Enjoy free shipping on any accessories purchased with the Friedrich PDE12K3SF.
- Friedrich PTAC Chasis Installation Instructions(PDF, 5.07 MB)
- Friedrich PTAC Drain Kit Installation Instructions(PDF, 154 KB)
- Friedrich PTAC Louver Installation Instructions(PDF, 569 KB)
- Friedrich PTAC Sleeve Extension Instructions(PDF, 438 KB)
- Friedrich PTAC Wall Sleeve Installation Guide(PDF, 1.36 MB)
- Friedrich PTAC Warranty(PDF, 20.0 KB)
- Friedrich R-410A E Series PTAC Brochure(PDF, 757 KB)
- Friedrich F Series PTAC Product Profile(PDF, 1.64 MB)
- Wire Gauge Sizes(PDF, 40.9 KB)